HomeCompanyCorporate profileOur workSite supportServicesRentalsAll equipment rentalMobile cranesTelehandlersMan liftsForkliftsWheel loadersExcavatorsBuses and coastersPorta cabinsPorta cabins for saleOffice containersLabour accommodationMosque containersToilet containersCanteen and kitchenSafety ProductsAll productsSafety products (PPE)ResourcesInsights and guidesDownloadsContactGet a proposal WhatsApp
Insights

How to Install a Temporary Horizontal Lifeline: 6 Steps

6 November 2026 · Safety Products Guides
Horizontal lifelines anchors supplied by Al Baraka Diyar in the UAE

To install a temporary horizontal lifeline, you anchor a tensioned line between two end anchors each rated to at least 12 kN (EN 795) or 22 kN (ANSI unengineered), set the span and sag according to the manufacturer’s chart, and limit the number of users to that stated on the label. Knowing how to install a temporary horizontal lifeline correctly is the difference between a system that arrests a fall and one that pulls its anchors out of the structure.

Why horizontal lifelines matter on GCC sites

Steel erection, roof sheeting, tank-top work and precast placement on UAE and Saudi sites all involve workers moving along an edge with no fixed anchor overhead. A horizontal lifeline (HLL) gives continuous tie-off along that path, so the worker is never unclipped. Abu Dhabi OSHAD CoP 23, Dubai Municipality Code of Construction Safety Practice and Saudi Aramco CSM all accept HLLs as a compliant fall-arrest anchorage, provided the system is installed by a competent person to the manufacturer’s instructions and the loads have been assessed.

Standards explained

How to install a temporary horizontal lifeline

1. Assess the structure

Confirm the beams, columns or parapets at each end can take the end-anchor load. A single-user fall on a 20 m span with a webbing line can generate 10 kN or more at each anchor because of the geometry. Where there is doubt, a structural engineer signs off, as Aramco CSM requires for anchors not already certified.

2. Fit the end anchors

Use beam clamps or girder trolleys sized to the flange width. Tighten to the specified torque and ensure the anchor sits at or above waist height to reduce fall distance.

3. Set the span and intermediate brackets

Most temporary kits allow spans of 20 m to 30 m between anchors; longer runs need intermediate brackets or a second kit. Shorter spans reduce sag and clearance.

4. Tension the line

Use the integral ratchet tensioner or turnbuckle until the sag indicator or tension gauge reads within the specified band. Over-tensioning increases end-anchor loads; under-tensioning increases fall distance.

5. Calculate clearance

Add line sag under load, the lanyard or SRL deployment, harness stretch and a 1 m safety margin. On a 20 m span this can exceed 5 m, which rules out many low-level applications unless a self-retracting lifeline is used in place of a lanyard.

6. Inspect, tag and brief

The competent person completes the installation checklist, fits a tag showing the date, installer, maximum users and clearance, and briefs the crew.

Specification table

ParameterTypical webbing kitTypical 8 mm cable kit
Maximum span20 m30 m (with intermediates up to 100 m)
Users at once22–4 depending on model
End-anchor minimum strength12 kN (EN) / 22 kN (ANSI)12 kN (EN) / 22 kN (ANSI)
Weight of kit5–8 kg12–20 kg
UV and sand resistanceModerate, inspect for frayingHigh, galvanised or stainless
Set-up time10–15 minutes20–30 minutes

Common mistakes

Inspection and replacement

Inspect the line, tensioner, shackles and anchors before each shift. Webbing lines in Gulf sun lose strength visibly after one or two seasons; replace at the first sign of chalking, stiffness or fibre damage. Cable lines last longer but must be retired if kinked, bird-caged or corroded. A documented inspection by a competent person is due at least every 12 months, and any system that has arrested a fall is withdrawn until the manufacturer confirms it can be returned to service.

Cost factors

Webbing kits are the economical option for short-term roofing and cladding jobs. Cable kits cost more but suit long tank and pipe-rack runs and survive the environment better. Engineered permanent systems with intermediate posts are a separate category and need a site survey.

A temporary horizontal lifeline should be designed by a competent person for the number of users and the clearance below. Inspect every temporary horizontal lifeline component before each use and after any fall. Record the anchor loads and installation checks for each temporary horizontal lifeline in the permit.

Where a lifeline cannot be installed safely from a ladder or structure, a man lift on rental gives a stable working platform for the installer.

Related guides: Self Retracting Lifeline vs Lanyard: 7 Facts for UAE Sites · How to Inspect a Safety Harness: 10-Point Site Checklist · Work at Height Rescue Plan Requirements: 5 Essentials

Key takeaways: Temporary Horizontal Lifeline

Al Baraka Diyar supplies EN 795 Type C temporary horizontal lifeline kits and engineered anchors alongside its complete safety products range for contractors in the UAE, with service to Saudi Arabia and India. For span calculations or a quotation, contact us.

Temporary Horizontal Lifeline: practical summary

temporary horizontal lifeline

This guide to temporary horizontal lifeline is written for UAE work sites, and also applies to our service areas in Saudi Arabia and India. If you need help applying temporary horizontal lifeline on your site, our team can confirm the right option and supply certified stock from the safety products range, or you can request a quotation. For the underlying standards, see the International Organization for Standardization.

Frequently asked questions

How many workers can use one temporary horizontal lifeline?

Only the number stated on the system label and in the manufacturer's manual, usually two for a webbing kit and up to four for an engineered cable kit tested to CEN/TS 16415. Exceeding this increases anchor loads beyond the tested values.

What strength must the end anchors have?

EN 795 requires a static strength of at least 12 kN per anchor, while ANSI Z359.6 asks for 22 kN for non-engineered anchors or twice the maximum arrest force for engineered ones. Anchors must be fixed to structural members, never to handrails or scaffold.

Can a horizontal lifeline be used for fall restraint instead of arrest?

Yes, and restraint is preferred where possible. The line is positioned and the lanyard length chosen so the worker cannot reach the edge. Loads are much lower, but the anchors and system must still be rated and installed by a competent person.

Get a proposal