HomeCompanyCorporate profileOur workSite supportServicesRentalsAll equipment rentalMobile cranesTelehandlersMan liftsForkliftsWheel loadersExcavatorsBuses and coastersPorta cabinsPorta cabins for saleOffice containersLabour accommodationMosque containersToilet containersCanteen and kitchenSafety ProductsAll productsSafety products (PPE)ResourcesInsights and guidesDownloadsContactGet a proposal WhatsApp
Insights

Electrical Insulating Glove Class and Testing Requirements UAE

6 November 2026 · Safety Products Guides
Electrical insulating gloves supplied by Al Baraka Diyar in the UAE

Electrical insulating glove class and testing requirements in the UAE follow IEC 60903 (and ASTM D120 for US-specified sites): gloves are rated Class 00 to Class 4 by maximum use voltage, must be electrically retested every six months once in service, and must be visually and air-inflation tested before every use. DEWA, ADDC, SEC and most EPC contractors write these rules directly into their electrical safety procedures, so selecting the correct class and keeping test records is a compliance matter, not just good practice.

Why insulating gloves matter on GCC electrical sites

Live-line work, switching operations, cable termination and testing in substations across Dubai, Abu Dhabi, Jubail and Yanbu all expose technicians to shock and arc-flash energy. Rubber insulating gloves are the primary barrier when the hands come within the restricted approach boundary defined in NFPA 70E. OSHAD and Dubai Municipality both expect contractors to apply the hierarchy of controls, but once de-energisation is not reasonably practicable, the glove system becomes the last line of defence. Heat is an added GCC factor: rubber ages faster when stored in hot vans or exposed to ozone from the sun and nearby equipment, which shortens the usable life compared with temperate climates.

Glove classes under IEC 60903 and ASTM D120

Both standards use the same class structure. Each class is tested at a proof voltage well above its maximum use voltage to give a safety margin.

ClassMax use voltage (AC)Proof test voltage (AC)Typical GCC application
00500 V2,500 VLV panels, building distribution boards
01,000 V5,000 VLV switchgear, motor control centres, solar DC strings
17,500 V10,000 V6.6 kV / 11 kV switching
217,000 V20,000 V11 kV and 13.8 kV distribution
326,500 V30,000 V33 kV rural and industrial feeders
436,000 V40,000 V33 kV live-line work

IEC 60903 also uses category letters: A (acid resistant), H (oil resistant), Z (ozone resistant), R (acid, oil and ozone), C (very low temperature). For UAE and Saudi outdoor use, category R or Z gloves are the sensible default because ozone cracking is a leading cause of early rejection.

Leather over-protectors are not optional

Rubber gloves are mechanically weak. A leather over-protector (protector glove) to EN 60903 Annex or ASTM F696 must be worn over Class 0 and above, and is strongly recommended for Class 00 where any abrasion risk exists. The protector must be shorter than the rubber glove by the specified cuff distance (typically 25 mm for Class 00 and 0, rising with class) so that the rubber cuff remains the first point of contact with a conductor. Never use the same leather protectors for mechanical work and then over insulating gloves: embedded metal particles or oil will contaminate the rubber.

Testing frequency and what the record must show

Common mistakes we see on UAE and Saudi sites

The most frequent failures are not the gloves themselves but the handling. Gloves stored flat under tools in a van develop creases that crack. Gloves left on a dashboard in July at 60 degrees Celsius age in weeks. Technicians choose Class 00 for 1,000 V DC solar work because they are thinner and more comfortable, when Class 0 is required. Leather protectors are swapped between pairs. Talc is replaced with lotion or hand cream, which attacks the rubber. Finally, expired gloves are kept as a spare pair, which defeats the purpose of the testing regime.

Storage and care in a hot climate

Store gloves cuff-down in a canvas or plastic glove bag, in the shade, away from ozone-producing equipment such as motors and welding machines. Keep them below 35 degrees Celsius where possible: a cab glove box is better than a pickup bed. Wash with mild soap and water only, dry fully away from direct sun, and apply glove powder before storage. Fold the cuff only if the manufacturer permits it. Replace both gloves of a pair if one fails; mixed-age pairs are a frequent audit finding.

Cost factors and specifying for a job

Price rises with class, length (280 mm versus 360 mm or 410 mm for shoulder-length live-line gloves) and category. Specify the class from the highest voltage the team will approach, not the typical one, and budget for retesting as a recurring cost. Keeping a float of tested spares avoids downtime while gloves are at the laboratory. Many contractors supplying DEWA, SEC and Aramco packages also require matching dielectric boots and 1000 V insulated tools under the same procedure, and arc-flash kits rated to the incident energy of the switchgear.

Select the glove class from the maximum working voltage of the job, with a margin. Mark the glove class on issue records and on storage bags. Retest gloves on schedule regardless of glove class.

Related guides: Chemical Resistant Glove Selection Chart: 5 Polymers Compared · Cut Resistant Glove Levels Explained: EN 388 A to F Guide · Arc Flash PPE Categories Explained: NFPA 70E for GCC Plants

Key takeaways: Glove Class

Al Baraka Diyar supplies IEC 60903 and ASTM D120 insulating gloves in every class with matching leather protectors and glove bags from Ajman, with delivery across the UAE, with service to Saudi Arabia and India. Browse our electrical insulating gloves range, see the full safety products catalogue, or contact our team with your voltage levels and quantities for a quotation.

Glove Class: practical summary

glove class

This guide to glove class is written for UAE work sites, and also applies to our service areas in Saudi Arabia and India. If you need help applying glove class on your site, our team can confirm the right option and supply certified stock from the safety products range, or you can request a quotation. For the underlying standards, see the International Organization for Standardization.

Frequently asked questions

How often must electrical insulating gloves be tested in the UAE?

In service, gloves need a dielectric retest every six months by an accredited laboratory, plus a visual and air-inflation check before each use. Gloves unused for 12 months after their last test must be retested before issue. Some ADNOC and Aramco procedures shorten the interval.

Which glove class is needed for 1000 V DC solar work?

Class 0 gloves, rated for 1,000 V maximum use, are the minimum for 1,000 V DC string work. Class 00 is limited to 500 V and is only suitable for low-voltage building distribution. Always wear leather over-protectors and check the DC rating noted by the manufacturer.

Can leather protectors be worn alone for electrical work?

No. Leather protectors provide only mechanical protection and have no voltage rating. They must always be worn over a tested rubber insulating glove of the correct class, and they must be kept clean and free of oil or metal particles.

Get a proposal

Chat on WhatsApp