A chemical resistant glove selection chart matches the glove polymer to the chemical family: nitrile for oils, fuels and many solvents; neoprene for acids, caustics and alcohols; butyl for ketones and esters; PVC for aqueous acids and bases; and multilayer laminate for aromatic and halogenated solvents. Under EN ISO 374-1:2016 the glove must also show its Type (A, B or C) and the code letters of the test chemicals it resisted for at least 30 minutes, which is the figure to check against your site’s chemical register.
Why chemical glove selection matters in GCC industry
Refineries, petrochemical plants, water treatment works, laboratories and construction sites across the UAE and Saudi Arabia handle a wide range of chemicals, from hydrochloric acid in well stimulation to amine solutions in gas sweetening and epoxy hardeners in coatings. Skin absorption and chemical burns are under-reported but serious. ADNOC HSE and Saudi Aramco CSM both require glove selection based on the safety data sheet (SDS) and a documented assessment, and Abu Dhabi OSHAD and Dubai Municipality expect the same. A general-purpose nitrile-coated work glove is not a chemical glove; its knitted liner wicks chemicals straight to the skin.
EN ISO 374 explained
EN ISO 374-1:2016 covers chemical risks. Gloves are tested for permeation against a list of 18 standard chemicals (coded A to T) to EN 16523-1 and classified: Type A resists at least six listed chemicals for 30 minutes or more; Type B at least three; Type C at least one for 10 minutes. The pictogram shows the Erlenmeyer flask with the code letters beneath it. EN ISO 374-5:2016 covers micro-organisms, with a VIRUS marking where tested.
Permeation level 1 to 6 corresponds to breakthrough times of over 10, 30, 60, 120, 240 and 480 minutes. In the US, ASTM F739 is the equivalent permeation method. Also check EN 388 for mechanical performance, because chemical gloves on construction sites still meet sharp edges.
Chemical resistant glove selection chart
| Chemical family | Examples on GCC sites | Nitrile | Neoprene | Butyl | PVC | Laminate |
|---|---|---|---|---|---|---|
| Petroleum oils and fuels | Diesel, crude, lube oil | Excellent | Good | Poor | Good | Excellent |
| Inorganic acids | HCl, H2SO4, HF (special) | Fair to good | Excellent | Excellent | Good | Excellent |
| Caustics | Sodium hydroxide, amines | Good | Excellent | Excellent | Good | Excellent |
| Alcohols and glycols | Methanol, MEG | Good | Excellent | Excellent | Fair | Excellent |
| Ketones and esters | MEK, acetone, ethyl acetate | Poor | Fair | Excellent | Poor | Excellent |
| Aromatic solvents | Toluene, xylene | Fair (short tasks) | Poor | Poor | Poor | Excellent |
| Halogenated solvents | Dichloromethane | Poor | Poor | Poor | Poor | Excellent |
| Epoxy resins and hardeners | Coatings, grouts | Good | Good | Good | Fair | Excellent |
This chart is a starting point. Always confirm against the manufacturer’s permeation data for the specific chemical, concentration and temperature, since breakthrough times fall sharply above 25 °C and Gulf ambient temperatures can double permeation rates.
How to choose: a four-step method
- List the chemicals from the SDS register with concentrations and contact type (splash, intermittent or immersion).
- Select the polymer using the chart, then check the manufacturer’s breakthrough table for each chemical.
- Set the thickness and length. Splash protection may need only 0.3 mm and a 30 cm cuff; immersion or tank cleaning needs 0.5 mm or more and 45 to 60 cm gauntlets.
- Check mechanical and grip needs. A flocked lining helps donning in heat; a sandpatch or diamond grip helps with wet drums and hoses.
Common mistakes
The most common is relying on thin disposable nitrile gloves for solvent work; they are splash gloves at best and permeate in minutes with ketones and aromatics. The second is reusing gloves after breakthrough; permeation is invisible, and once the chemical is inside the polymer it keeps migrating. The third is using the wrong glove for hydrofluoric acid, which needs specific neoprene or laminate gloves and emergency calcium gluconate gel. The fourth is storing gloves in sunlight where ozone and UV degrade natural rubber and neoprene. Finally, chemical gloves are often not sized, and a loose gauntlet lets chemical run inside at the cuff.
Decontamination, inspection and replacement
Inspect gloves before each use by inflating and checking for pinholes. Rinse reusable gloves before removal to avoid contaminating the inside. Set a replacement rule based on the lowest breakthrough time for the chemicals in use, not on visible damage, and log changes for Type A gloves used in immersion. Store in a cool, dark cabinet; in Gulf summer storage temperatures, shelf life of natural rubber and neoprene drops noticeably.
Use a glove selection chart with the chemical safety data sheet, not instead of it. Update your glove selection chart when new chemicals arrive on site. Post the glove selection chart at chemical stores.
Related guides: Cut Resistant Glove Levels Explained: EN 388 A to F Guide · Electrical Insulating Glove Class and Testing Requirements UAE · Nitrile vs Latex vs Vinyl Disposable Gloves: Which to Buy
Key takeaways: Glove Selection Chart
- Match the polymer to the chemical family, then verify breakthrough time with manufacturer data.
- Check the EN ISO 374-1 Type and code letters on the glove.
- Heat shortens breakthrough; allow for Gulf temperatures.
- Disposable and coated work gloves are not chemical gloves.
- Replace on time, not on appearance.
Al Baraka Diyar supplies EN ISO 374 chemical-resistant gloves in nitrile, neoprene, butyl, PVC and laminate, plus chemical protective suits and the full range of safety products for the UAE, Saudi Arabia and India. Contact us with your chemical register for a selection recommendation and quotation.
Glove Selection Chart: practical summary
This guide to glove selection chart is written for UAE work sites, and also applies to our service areas in Saudi Arabia and India. If you need help applying glove selection chart on your site, our team can confirm the right option and supply certified stock from the safety products range, or you can request a quotation. For the underlying standards, see the International Organization for Standardization.
Frequently asked questions
What do the letters under the EN ISO 374 flask mean?
Each letter (A to T) is a standard test chemical, for example K for sodium hydroxide 40 per cent, J for n-heptane and L for sulphuric acid 96 per cent. The glove resisted each listed chemical for at least 30 minutes in permeation testing.
Are nitrile gloves resistant to acetone?
No. Acetone and other ketones permeate nitrile within minutes. Butyl rubber gloves give the best protection against ketones and esters, and multilayer laminate gloves are a good alternative for mixed solvent work.
How does heat affect chemical glove breakthrough time?
Permeation rates roughly double for every 10 °C rise. Breakthrough times published at 23 °C can be halved or worse at Gulf site temperatures, so choose a thicker glove or shorter change interval for summer work.