Body protection & workwear · Premium & specialised · HSE-mandated
Arc-Flash Protection Kits in UAE, KSA & India
An arc-flash kit is a matched set of arc-rated clothing, hood or face shield, insulated gloves and accessories that protects electrical workers from the heat, light and pressure of an electric arc during switching, testing and live maintenance.
Site quantities · CE / ANSI certificates · Delivery across UAE, KSA & India

An arc flash releases intense heat and a pressure wave within milliseconds when electrical insulation fails or a fault occurs across energised conductors. Arc-rated PPE is specified by its arc thermal performance value (ATPV) in calories per square centimetre and selected against the incident energy calculated for each panel or switchgear. Kits group a coverall or jacket and bib, an arc-rated hood with face shield or a balaclava and shield, Class 0 to Class 2 insulating gloves with leather protectors, and a storage bag.
Electrical contractors, utilities, data centre operators, district cooling plants, oil and gas facilities and industrial maintenance teams in the Gulf need arc-rated PPE wherever switching above low-voltage thresholds takes place. Al Baraka Diyar supplies 8, 12, 40 and 65 cal/cm² kits with certificates from Ajman to Dubai, Abu Dhabi and Jebel Ali, and to customers in Saudi Arabia and India, and can assemble kits to the categories named in a client arc-flash study.
Key features
- Arc-rated coverall or jacket and bib overall with ATPV 8 to 65 cal/cm²
- Hood with anti-fog arc-rated face shield, or balaclava and chin-guarded shield for 8–12 cal
- Class 0, 1 or 2 rubber insulating gloves with leather protectors
- Arc-rated hard hat, hearing protection and safety glasses included in full kits
- Multi-layer FR fabrics with inherent aramid, modacrylic or FR cotton
- Supplied in a labelled storage bag for shift handover and inspection
Technical specifications
| Standards | NFPA 70E (PPE categories 1–4); ASTM F1506 (clothing); ASTM F2178 (face/hood); IEC 61482-2 |
|---|---|
| Glove standard | ASTM D120 / IEC 60903 Class 00 to Class 2 |
| Kit ratings | 8, 12, 25, 40 and 65 cal/cm² (ATPV) |
| NFPA 70E categories | Cat 2 (8 cal), Cat 3 (25 cal), Cat 4 (40 cal) |
| Garment style | Coverall; or jacket and bib overall |
| Hood | Arc-rated hood with face shield; ventilated hood option for 40+ cal |
| Sizes | M to 4XL garments; glove sizes 8 to 11 |
| Colours | Grey, navy, khaki |
| Packaging | Complete kit in storage bag; individual items on request |
Variants available
- 8 cal/cm² kit: coverall, balaclava, face shield, Class 0 gloves
- 12 cal/cm² daily-wear kit with jacket and bib overall
- 40 cal/cm² kit: coverall, hood with shield, Class 2 gloves, bag
- 65 cal/cm² kit for high-energy switchgear
- Arc-rated hood and face shield only
- Insulated gloves and leather protectors replacement set
Brands we supply
Applications across GCC sites
substation switching, transformer maintenance and distribution panels
MCC rooms, switchgear and electrical maintenance on ADNOC and Aramco sites
UPS, switchboard and chiller plant electrical work
temporary power distribution and generator connections
inverter, combiner box and medium-voltage interconnection work
motor control centres and VFD panels in factories
What site HSE teams expect
In the UAE, DEWA, ADDC and Abu Dhabi OSHAD electrical safety guidance expect employers to assess arc-flash risk and provide arc-rated PPE, commonly following NFPA 70E categories. ADNOC and Saudi Aramco electrical safety standards require an arc-flash study for switchgear, labelling of incident energy and PPE matched to the calculated level, with 40 cal/cm² kits typical for medium-voltage switching. Many UAE facilities now accept IEC 61482-2 garments alongside ASTM F1506.
Each garment should carry an ATPV or EBT label, standard references and care instructions; rubber insulating gloves must be electrically retested every six months in service per ASTM D120 and IEC 60903 practice, and visually inspected before each use. Face shields are replaced when scratched or clouded. Al Baraka Diyar supplies manufacturer test reports and glove test dates with each kit so facilities can enter them in the PPE register.
How to choose
- Match the kit ATPV to the incident energy on the equipment label or arc-flash study
- Choose 8 or 12 cal daily-wear garments for routine panel work and a 40 cal kit for switching
- Select glove class by voltage: Class 0 up to 1 kV, Class 1 to 7.5 kV, Class 2 to 17 kV
- Prefer ventilated hoods and lighter layered systems for summer work in plant rooms
Frequently asked questions
What arc rating do I need for switchgear in the UAE?
The required rating comes from an arc-flash study of each panel, which many ADNOC, Aramco and DEWA-connected facilities now carry out. Low-voltage panels often fall into 8 to 12 cal/cm², while medium-voltage switching commonly requires a 40 cal/cm² kit. Do not guess ratings without a study.
Is an arc flash kit mandatory in the UAE?
UAE regulations require employers to protect workers from electrical hazards and OSHAD and client standards reference NFPA 70E or IEC 61482 for arc-rated PPE. On ADNOC, Aramco and utility sites arc-rated PPE is a written requirement for energised switching and testing.
How often must insulating gloves be tested?
Rubber insulating gloves are dielectrically retested every six months once in service, and gloves unused for twelve months are tested before issue. Each glove carries a test date stamp. Daily air tests and visual checks for cuts and ozone cracking are also expected.
What is the difference between ATPV and EBT?
Both are arc ratings in cal/cm². ATPV is the energy at which there is a 50% chance of a second-degree burn through the fabric; EBT is the energy at which the fabric breaks open. The label shows whichever is lower, and either can be used to select PPE.
Can you supply arc flash kits with certificates for ADNOC or Aramco approval?
Yes. Al Baraka Diyar provides kits with manufacturer certificates to ASTM F1506, ASTM F2178 and IEC 61482-2, plus glove test certificates, for submission to client HSE departments. Stock 40 cal kits ship from Ajman within days; custom configurations take two to four weeks.
Quote for Arc-Flash Protection Kits
Tell us quantity, sizes and delivery location. We reply with an itemised quotation and certificates within one working day.
Related safety products

Electrical Insulating Gloves
Electrical insulating gloves are natural-rubber or latex gloves tested to IEC 60903 or ASTM D120 that protect the wearer from electric shock…

Dielectric Boots & Insulated Tools
Dielectric boots are electrically insulating safety footwear tested to EN 50321 or ASTM F2413 EH, and insulated tools are hand tools rated t…

FR Coveralls (NFPA 2112 / EN ISO 11612)
FR coveralls are flame-resistant one-piece garments made from inherent aramid or treated cotton fabrics that self-extinguish and do not melt…
Need Arc-Flash Protection Kits for your site?
Send us the quantity, sizes and delivery location, or the client standard you must meet, and we will return an itemised quotation with certificates within one working day.