Gas detection & confined space · Premium & specialised · HSE-mandated
Bump-Test & Calibration Stations in UAE, KSA & India
Bump-test and calibration stations are docking units and calibration gas kits that verify a gas detector's sensors and alarms respond correctly, adjust its accuracy against certified gas mixtures and record the result for compliance.
Site quantities · CE / ANSI certificates · Delivery across UAE, KSA & India

A gas detector is only trustworthy if it is proven to respond. A bump test exposes the instrument briefly to a known gas concentration to confirm sensors and alarms work; calibration adjusts the reading to match a certified mixture. Automatic docking stations perform both, charge the detector, update firmware and log results. Manual calibration kits use a calibration gas cylinder, a fixed-flow regulator, tubing and a calibration cap.
Every ADNOC, Saudi Aramco, DEWA and municipal confined-space programme in the Gulf depends on daily bump testing and periodic calibration with traceable gas. Al Baraka Diyar supplies docking stations, single- and multi-station systems, certified 4-gas and single-gas calibration cylinders, regulators and demand-flow kits across the UAE (Ajman, Dubai, Abu Dhabi), Saudi Arabia and India to keep detector fleets audit-ready.
Key features
- Automatic docking stations bump test, calibrate, charge and log Honeywell BW, Dräger, MSA and Industrial Scientific detectors
- Certified quad-gas mixtures (CH4 or pentane, O2, CO, H2S) in 34 L, 58 L and 103 L aluminium cylinders
- Single-gas H2S, CO, SO2, NH3, Cl2 and zero-air cylinders for specialist sensors
- Fixed-flow 0.5 L/min and demand-flow regulators compatible with C10 cylinder threads
- Data output to PC or cloud fleet-management software with exportable compliance records
- Multi-bay stations test up to 10 detectors at once for shift-start throughput on large sites
Technical specifications
| Calibration gas standard | Traceable to NIST / ISO 17025 lab; certificate of analysis supplied per cylinder |
|---|---|
| Typical 4-gas mixture | 2.5 % CH4 (50 % LEL), 18 % O2, 100 ppm CO, 25 ppm H2S, balance N2 |
| Typical single-gas | 25 ppm H2S; 100 ppm CO; 10 ppm SO2; 50 ppm NH3; 20.9 % O2 zero air |
| Cylinder sizes | 34 L, 58 L, 103 L (non-refillable aluminium) |
| Regulators | 0.5 L/min fixed flow; demand flow for pumped detectors; C10 thread |
| Station types | Single-bay dock; multi-bay 4 to 10 units; portable field dock |
| Shelf life of gas | Typically 12–36 months depending on mixture (H2S and Cl2 shorter) |
| Hazardous-area use | Stations for safe-area use only; field calibration with portable kits |
| Packaging | Cylinders singly or cartons of 4–6; stations individually boxed |
Variants available
- Single-bay docking station with charger
- Multi-bay (4, 6 or 10) docking system with gas manifold
- Portable manual calibration kit: 58 L quad-gas, regulator, tubing, cap
- 34 L 25 ppm H2S single-gas cylinder with regulator
- 103 L quad-gas cylinder for high-throughput sites
- Zero-air and fresh-air calibration cylinders
Brands we supply
Applications across GCC sites
shift-start bump testing of entry teams on ADNOC and Saudi Aramco plants
turnaround detector fleets of several hundred units in Ruwais, Jubail and Yanbu
municipal sewer entry crews for Dubai Municipality and ADSSC
tunnelling and deep-excavation contractors with authorised gas testers
refinery and power-plant maintenance workshops and tool cribs
port, tanker and warehouse gas-testing stations
What site HSE teams expect
Gas detector manufacturers and GCC operators typically require a bump test before each day's use and a full calibration at least every 180 days; some ADNOC and Saudi Aramco contracts specify monthly calibration. Calibration gas must be within its expiry date and traceable to a national standard, with the certificate of analysis retained. Docking stations are the normal way to evidence these checks for OSHAD, Dubai Municipality and Aramco CSM audits.
Calibration gas cylinders are compressed-gas products and should be stored upright, below 50 °C and out of direct sun, which matters in Gulf summers. Expired or empty cylinders are disposed of as scrap metal once vented. Al Baraka Diyar supplies cylinders with certificates of analysis and safety data sheets and advises on cylinder sizes to match fleet size and calibration frequency.
How to choose
- Match the calibration gas to the detector's LEL calibration gas (methane or pentane) and sensor set
- Choose multi-bay docking for fleets above 20 detectors; portable kits for remote or field crews
- Size cylinders to consumption: 103 L lasts longer per cylinder but check expiry versus usage rate
- Use demand-flow regulators for pumped detectors and fixed-flow for diffusion units and docks
Frequently asked questions
What is the difference between a bump test and a calibration?
A bump test applies gas briefly to confirm every sensor responds and the alarms activate; it does not adjust readings. Calibration applies a certified gas concentration and adjusts the detector so its reading matches. Bump testing is daily; calibration is periodic, typically every six months or as the client specifies.
Which calibration gas do I need for a 4-gas detector?
Most 4-gas detectors use a quad mixture of 2.5 % methane (50 % LEL), 18 % oxygen, 100 ppm carbon monoxide and 25 ppm hydrogen sulphide in nitrogen. Some detectors are calibrated on pentane rather than methane; check the manufacturer's specification before ordering.
How long does calibration gas last?
Shelf life depends on the mixture. Methane, CO and O2 blends commonly carry 24 to 36 months; H2S mixtures are often 12 to 24 months and chlorine or ammonia shorter. Hot storage shortens life. Each cylinder carries an expiry date and should not be used after it.
Are docking stations required by ADNOC or Saudi Aramco?
They are not mandated by name, but both operators require documented bump tests and calibrations within set intervals. A docking station is the practical way to produce those records for a large fleet, and most contractors on Aramco and ADNOC sites standardise on one.
Can Al Baraka Diyar supply calibration gas in bulk across the Gulf?
Yes. Quad-gas and single-gas cylinders, regulators and docking stations are supplied in bulk quantities from Ajman to Dubai, Abu Dhabi, Saudi Arabia and India, with certificates of analysis. Standing orders can be arranged so cylinders arrive before expiry of the previous batch.
Quote for Bump-Test & Calibration Stations
Tell us quantity, sizes and delivery location. We reply with an itemised quotation and certificates within one working day.
Related safety products

Multi-Gas Detectors (O2 / LEL / CO / H2S)
Multi-gas detectors are portable instruments that simultaneously measure oxygen, flammable gas (LEL), carbon monoxide and hydrogen sulphide,…

Personal H2S Gas Monitors
Personal H2S gas monitors are compact, body-worn single-gas detectors with an electrochemical sensor that alarm audibly, visually and by vib…

Confined-Space Entry & Rescue Kits
Confined-space entry and rescue kits are tripod-based systems combining an EN 795 anchor tripod, an EN 1496 rescue winch and an EN 360 self-…
Need Bump-Test & Calibration Stations for your site?
Send us the quantity, sizes and delivery location, or the client standard you must meet, and we will return an itemised quotation with certificates within one working day.