HomeCompanyCorporate profileOur workSite supportServicesRentalsAll equipment rentalMobile cranesTelehandlersMan liftsForkliftsWheel loadersExcavatorsBuses and coastersPorta cabinsPorta cabins for saleOffice containersLabour accommodationMosque containersToilet containersCanteen and kitchenSafety ProductsAll productsSafety products (PPE)ResourcesInsights and guidesDownloadsContactGet a proposal WhatsApp

Respiratory protection · Premium & specialised · HSE-mandated

Self-Contained Breathing Apparatus (SCBA) in UAE, KSA & India

Self-contained breathing apparatus (SCBA) is a positive-pressure respiratory protection system in which the wearer carries a compressed-air cylinder on a backplate and breathes through a demand valve and full-face mask, independent of the surrounding atmosphere.

EN 137:2006 Type 2NFPA 1981 (US sets)mask EN 136 Class 3cylinder EN 12245 / ISO 11119

Site quantities · CE / ANSI certificates · Delivery across UAE, KSA & India

SCBA set with carbon fibre cylinder, backplate and full face mask

SCBA provides breathable air from a cylinder carried by the wearer, allowing entry into atmospheres that are oxygen-deficient, toxic or immediately dangerous to life and health. A typical set comprises a composite or steel cylinder of 6 to 9 litres at 300 bar, a backplate and harness, a pressure reducer, a positive-pressure demand valve and a full-face mask to EN 136 Class 3. Duration is commonly 30 to 60 minutes depending on cylinder and work rate.

Industrial fire brigades, plant emergency response teams, H2S rescue crews, confined-space rescue teams and Civil Defence contractors across the Gulf use SCBA to EN 137 Type 2 or NFPA 1981. Al Baraka Diyar supplies SCBA sets, spare cylinders, masks and cascade filling systems across the UAE (Ajman, Dubai, Abu Dhabi), Saudi Arabia and India for ADNOC, Saudi Aramco and petrochemical sites.

Key features

  • EN 137 Type 2 certified, including flame engulfment test, for industrial fire and rescue
  • Carbon-composite 6.8 L or 9 L 300 bar cylinders giving 30 to 60 minutes nominal duration
  • Positive-pressure first-breath demand valve with full-face mask to EN 136 Class 3
  • Adjustable backplate and padded harness with quick-release buckles and belt pivot
  • Integrated gauge and whistle warning at 55 bar, electronic HUD and PASS alarm on premium sets
  • Quick-connect cylinder valve and optional rescue second-man attachment for casualty air sharing

Technical specifications

Standards EN 137:2006 Type 2; NFPA 1981 (US sets); mask EN 136 Class 3; cylinder EN 12245 / ISO 11119
Cylinder options 6 L steel 300 bar; 6.8 L composite 300 bar; 9 L composite 300 bar; twin-cylinder sets
Nominal duration 30, 45 or 60 minutes at 40 L/min
Mask Full-face, silicone or EPDM, positive pressure, panoramic polycarbonate visor
Harness Flame-retardant, anti-static webbing; backplate of carbon fibre or polyamide composite
Warning Mechanical whistle at 50–60 bar; electronic HUD and PASS optional
Weight Approximately 8–13 kg complete with full composite cylinder
Service Annual service; cylinder hydrostatic test every 5 years (composite 15-year life)
Packaging Set in carry case; spare cylinders and masks boxed individually

Variants available

  • Industrial SCBA set with 6.8 L composite cylinder, 30 minutes
  • Fire-brigade SCBA to EN 137 Type 2 with HUD and PASS
  • 9 L composite 60-minute SCBA for long-duration rescue
  • Twin-cylinder 2×6.8 L SCBA for extended operations
  • Spare composite and steel cylinders, 300 bar
  • SCBA wall cabinets and cascade cylinder filling systems

Brands we supply

DrägerMSAHoneywellScott Safety (3M)InterspiroSpasciani

Applications across GCC sites

Oil & gas

H2S emergency response and rescue teams on ADNOC and Saudi Aramco sites

Petrochemical

plant fire brigades and confined-space rescue in Ruwais, Jubail and Yanbu

Fire services

industrial Civil Defence contractors and airport fire crews

Industrial

ammonia refrigeration and chlorine emergencies in food and water plants

Marine

tanker and port emergency response at Jebel Ali, Fujairah and Dammam

Utilities

chlorine rooms at desalination and water treatment plants

Compliance in the UAE & GCC

What site HSE teams expect

UAE Civil Defence and Abu Dhabi OSHAD require emergency response teams to be equipped with positive-pressure SCBA to EN 137 or NFPA 1981, and ADNOC HSE and Saudi Aramco CSM specify SCBA for H2S rescue, confined-space rescue and firefighting. Saudi Aramco fire protection standards typically call for NFPA 1981 sets with integrated PASS. Wearers must be face-fit tested and trained, and sets must be held on a documented inspection schedule.

SCBA requires a monthly or pre-use check, an annual service by a competent technician, and periodic cylinder hydrostatic testing, commonly every five years. Composite cylinders have a finite life, often 15 years. Breathing air must meet EN 12021 purity. Al Baraka Diyar supplies sets with CE certificates, cylinder test certificates and user manuals, and can arrange local service support.

How to choose

  1. Choose EN 137 Type 2 or NFPA 1981 sets for fire brigades; industrial Type 2 sets suffice for H2S and rescue
  2. Select 30-minute composite cylinders for weight and manoeuvrability; 45 or 60 minutes for extended rescue
  3. Specify HUD and PASS alarms where wearers may operate alone or in smoke-filled areas
  4. Standardise masks and cylinder valves across the site so spares and filling equipment are interchangeable

Frequently asked questions

What is the difference between EN 137 Type 1 and Type 2 SCBA?

Type 2 sets pass an additional flame-engulfment and heat-resistance test and are intended for firefighting; Type 1 are for general industrial use. Most GCC industrial emergency teams specify Type 2 so a single set covers both H2S rescue and fire response, which aligns with ADNOC and Civil Defence expectations.

How long does an SCBA cylinder last?

Nominal duration is calculated at 40 litres per minute: a 6.8 L 300 bar cylinder gives about 45 minutes nominal but roughly 30 minutes in practical use at higher work rates. A 9 L cylinder gives around 60 minutes nominal. The whistle warns at approximately 55 bar remaining.

How often must SCBA be inspected and serviced?

Typical practice is a visual check after each use and monthly, an annual service with flow test by a trained technician, and cylinder hydrostatic testing every five years. Composite cylinders are retired at the end of their manufacturer-stated life, usually 15 years. Records are kept for Civil Defence and Aramco audits.

Is face-fit testing required for SCBA in the UAE?

Yes. Positive-pressure SCBA still depends on a good face seal, and ADNOC, Saudi Aramco and OSHAD-aligned employers typically require quantitative or qualitative face-fit testing for each wearer with the specific mask model. Wearers must be clean-shaven in the seal area.

Can you supply SCBA in bulk with cylinders and filling equipment?

Al Baraka Diyar supplies complete SCBA sets, spare cylinders, masks, storage cabinets and cascade filling systems in bulk quantities from Ajman to Dubai, Abu Dhabi, Saudi Arabia and India. Lead times depend on cylinder availability; standard 30-minute sets are commonly held in regional stock.

Request a quote

Quote for Self-Contained Breathing Apparatus (SCBA)

Tell us quantity, sizes and delivery location. We reply with an itemised quotation and certificates within one working day.

Download technical datasheet (PDF)

Get a quotation

Need Self-Contained Breathing Apparatus (SCBA) for your site?

Send us the quantity, sizes and delivery location, or the client standard you must meet, and we will return an itemised quotation with certificates within one working day.

Chat on WhatsApp