HomeCompanyCorporate profileOur workSite supportServicesRentalsAll equipment rentalMobile cranesTelehandlersMan liftsForkliftsWheel loadersExcavatorsBuses and coastersPorta cabinsPorta cabins for saleOffice containersLabour accommodationMosque containersToilet containersCanteen and kitchenSafety ProductsAll productsSafety products (PPE)ResourcesInsights and guidesDownloadsContactGet a proposal WhatsApp

Respiratory protection · Premium & specialised · HSE-mandated

Supplied-Air (Airline) Respirators in UAE, KSA & India

Supplied-air respirators are airline breathing systems that deliver filtered compressed breathing air through a hose from a compressor or cylinder bank to a mask, hood or helmet, giving unlimited duration for work in toxic or oxygen-deficient atmospheres.

EN 14593-1 (demand valve)EN 14594 (continuous flowClass 1A–4B)EN 12021 (air quality)

Site quantities · CE / ANSI certificates · Delivery across UAE, KSA & India

Supplied-air airline respirator with full face mask and coiled hose

A supplied-air or airline respirator removes the duration limit of SCBA by piping breathing air from a remote source. The system consists of a breathing-air compressor or cylinder cart, a filtration and CO-monitoring panel, airline hose up to 50 m, a belt-mounted flow or demand regulator and a facepiece. Facepieces range from constant-flow hoods and abrasive-blasting helmets to full-face masks with positive-pressure demand valves to EN 14593-1, and some include an escape cylinder for emergencies.

Abrasive blasters, spray painters, tank cleaners, confined-space entrants and chemical handlers in Gulf shipyards, fabrication yards, refineries and water plants depend on airline respirators. Al Baraka Diyar supplies complete systems and components across the UAE (Ajman, Dubai, Abu Dhabi), Saudi Arabia and India, including blasting helmets, filtration panels, hoses and EN 12021 breathing-air testing support.

Key features

  • EN 14593-1 demand-valve full-face systems and EN 14594 constant-flow hoods, helmets and visors
  • Belt-mounted regulator with flow adjustment and audible low-pressure warning
  • Airline hose in 10 m sections to 50 m, anti-static, with quick-connect safety couplings
  • Breathing-air filtration panels with coalescing, activated-carbon stages and CO monitor to EN 12021
  • Combined airline and escape-cylinder sets for IDLH and confined-space entry
  • Abrasive-blasting helmets with cape, hearing protection and climate tube for Gulf heat

Technical specifications

Standards EN 14593-1 (demand valve); EN 14594 (continuous flow, Class 1A–4B); EN 12021 (air quality); EN 136 masks
Air source Breathing-air compressor, cylinder cart or plant air via filtration panel
Supply pressure Typically 4–8 bar at the belt regulator
Flow Constant flow 170–300 L/min for hoods; demand on inhalation for masks
Hose 10, 20, 30 and 50 m lengths, max 50 m (or per manufacturer)
Facepieces Full-face mask, half mask, loose hood, blasting helmet, welding visor
Escape cylinder Optional 2 L / 200 bar for 10–15 minutes
Filtration Particulate, coalescing, carbon; CO alarm 10 ppm; optional cooler/dryer
Packaging Kits in cases; hose per reel; filters boxed individually

Variants available

  • Constant-flow airline hood kit with belt regulator and 10 m hose
  • Full-face demand-valve airline respirator to EN 14593-1
  • Airline respirator with escape cylinder for confined-space entry
  • Abrasive-blasting helmet system with cape and climate control
  • 4-outlet breathing-air filtration panel with CO monitor
  • Portable cylinder air cart with manifold for 2–4 users

Brands we supply

3MHoneywellDrägerMSASundströmRPB Safety

Applications across GCC sites

Shipbuilding & fabrication

abrasive blasting and painting in Dubai Maritime City, Hamriyah and Dammam yards

Oil & gas

tank cleaning and vessel entry on ADNOC and Saudi Aramco turnarounds

Petrochemical

catalyst handling and reactor entry where nitrogen inerting is used

Construction

spray-applied coatings and polyurethane foam in enclosed spaces

Industrial

pharmaceutical and chemical dispensing where filters offer insufficient protection

Utilities

chlorine and ozone rooms at desalination plants

Compliance in the UAE & GCC

What site HSE teams expect

Abu Dhabi OSHAD, Dubai Municipality and ADNOC HSE standards require supplied-air respiratory protection where contaminant levels exceed the capacity of filtering respirators, where oxygen may be below 19.5 % or where the contaminant is unknown. Saudi Aramco CSM and GI requirements for abrasive blasting and confined-space entry commonly specify airline systems with an escape cylinder for IDLH atmospheres. Breathing air must meet EN 12021 or equivalent for oxygen, CO, CO2, oil and water content.

Compressed breathing air should be tested periodically, typically every three months, and filtration elements changed per manufacturer hours. Masks require face-fit testing; hoods and helmets do not. Hoses, couplings and regulators are inspected before each use and serviced annually. Al Baraka Diyar supplies systems with CE certificates and EN 12021 air-quality test support.

How to choose

  1. Choose demand-valve full-face systems for IDLH or unknown atmospheres; constant-flow hoods for blasting and painting
  2. Add an escape cylinder wherever the hose could be severed or the air source could fail during tank entry
  3. Size the compressor and filtration panel to the number of simultaneous users and their flow rates
  4. Specify a climate tube or vortex cooler for blasting helmets used in Gulf summer temperatures

Frequently asked questions

When is a supplied-air respirator required instead of a filter respirator?

Airline systems are needed when oxygen may be below 19.5 %, when contaminant concentrations exceed the assigned protection factor of filtering respirators, when contaminants have poor warning properties or are unknown, and for abrasive blasting. They are also used where filter changes would be too frequent to be practical.

Can I run an airline respirator from the site compressor?

Only through a breathing-air filtration panel with coalescing, particulate and activated-carbon stages and a carbon-monoxide alarm, and with regular EN 12021 air tests. Plant air contains oil, water and sometimes CO. A dedicated oil-free breathing-air compressor is the preferred option on most Gulf sites.

What is the maximum airline hose length?

Most systems are certified for up to 50 metres of hose, though some demand-valve systems allow more. Pressure drop increases with length, so the belt regulator supply pressure must be set to the manufacturer's table for the hose length used.

Do airline respirators need face-fit testing?

Tight-fitting full-face and half masks do, typically annually and whenever the model changes. Loose-fitting hoods, helmets and visors to EN 14594 do not, which makes them the usual choice for blasting crews, bearded workers and sites with high labour turnover.

Can Al Baraka Diyar supply complete airline systems in bulk?

Yes. Full systems for blasting, painting and confined-space entry, including compressors, filtration panels, hoses, masks and escape cylinders, are supplied from Ajman to Dubai, Abu Dhabi, Saudi Arabia and India, with CE documentation and spares packages sized to the site.

Request a quote

Quote for Supplied-Air (Airline) Respirators

Tell us quantity, sizes and delivery location. We reply with an itemised quotation and certificates within one working day.

Download technical datasheet (PDF)

Get a quotation

Need Supplied-Air (Airline) Respirators for your site?

Send us the quantity, sizes and delivery location, or the client standard you must meet, and we will return an itemised quotation with certificates within one working day.

Chat on WhatsApp