HomeCompanyCorporate profileOur workSite supportServicesRentalsAll equipment rentalMobile cranesTelehandlersMan liftsForkliftsWheel loadersExcavatorsBuses and coastersPorta cabinsPorta cabins for saleOffice containersLabour accommodationMosque containersToilet containersCanteen and kitchenSafety ProductsAll productsSafety products (PPE)ResourcesInsights and guidesDownloadsContactGet a proposal WhatsApp

Signage & lockout · Premium & specialised · HSE-mandated

Lockout-Tagout (LOTO) Kits in UAE, KSA & India

Lockout-tagout kits are sets of safety padlocks, hasps, circuit breaker, valve and plug lockouts and warning tags used to isolate energy sources and prevent machinery or circuits being re-energised while people are working on them.

OSHA 29 CFR 1910.147ANSI/ASSP Z244.1-2016EN 50110-1 for electrical isolationISO 45001 energy control

Site quantities · CE / ANSI certificates · Delivery across UAE, KSA & India

Lockout-Tagout - Lockout tagout kit with red padlocks, hasps and tags

A lockout-tagout kit gives an electrician, mechanic or permit holder everything needed to isolate and secure a machine, circuit or pipeline under a permit-to-work. Non-conductive safety padlocks, each keyed differently and labelled to the individual, are applied through multi-lock hasps so every worker holds their own key. Device-specific lockouts fit miniature and moulded-case breakers, gate and ball valves, plugs and cable sockets, while tags identify who applied the lock, when and why, in line with OSHA 29 CFR 1910.147 and ISO 45001 energy control practice.

Across the GCC, LOTO kits are used by maintenance teams in refineries, power and desalination plants, district cooling, factories, warehouses with conveyors, and by MEP contractors on construction sites. Saudi Aramco GI 6.012 isolation practice and ADNOC HSE standards require individual locks and tags on every isolation point. Al Baraka Diyar supplies LOTO kits, stations and consumables in site quantities from Ajman across the UAE, with service to Saudi Arabia and India, with Arabic and English tags available.

Key features

  • Kits assembled to OSHA 29 CFR 1910.147 and ANSI/ASSP Z244.1 energy control requirements
  • Non-conductive nylon safety padlocks keyed differently, keyed alike or master keyed, with laser-engraved names
  • Steel and nylon hasps take up to 6 padlocks so each worker locks the same isolation point
  • Universal MCB, MCCB and pin-type breaker lockouts, plus gate valve and ball valve lockouts
  • Durable PVC or polyester tags with Arabic and English wording and write-on fields
  • Supplied in a lockable case, pouch or wall-mounted station for electrical or mechanical teams

Technical specifications

Standards OSHA 29 CFR 1910.147; ANSI/ASSP Z244.1-2016; EN 50110-1 for electrical isolation; ISO 45001 energy control
Padlock body Nylon or reinforced thermoplastic, 38 mm wide, 6 mm steel or nylon shackle
Keying Keyed differently, keyed alike by group, or master keyed systems
Hasps 25 mm and 38 mm jaw, steel or nylon, 6 padlock capacity
Breaker lockouts Universal MCB, pin-in, pin-out, tie-bar and MCCB devices
Valve lockouts Gate valve 25–330 mm wheels, ball valve 12–200 mm handles, butterfly and plug lockouts
Tags PVC or polyester 75 × 160 mm, Arabic/English, with nylon cable ties
Kit formats Personal pouch, electrical kit, valve kit, group lock box, wall station of 10–20 locks
Packaging Each kit boxed with contents list; padlocks individually bagged with 2 keys

Variants available

  • Personal electrical LOTO pouch with 2 padlocks and breaker lockouts
  • Mechanical valve lockout kit in hard case
  • Group lock box for permit-to-work isolations
  • Wall-mounted LOTO station with 10 or 20 padlocks
  • Cable lockout and plug lockout set
  • Bulk safety padlocks engraved with employee names

Brands we supply

Master LockBradyABUSPanduitLockout SafetyElecpopular

Applications across GCC sites

Oil & gas

valve and pump isolations under permit at refineries, gas plants and tank farms

Power & water

breaker and switchgear lockout at substations, power stations and desalination plants

Industrial

machine guarding and conveyor isolation in factories, cement plants and steel mills

Construction

temporary electrical distribution and MEP commissioning lockouts on UAE sites

Logistics

automated conveyor and dock leveller isolation in Jebel Ali and Riyadh warehouses

Facilities

HVAC, chiller and lift isolation in commercial towers and district cooling plants

Compliance in the UAE & GCC

What site HSE teams expect

UAE regulations under Abu Dhabi OSHAD Codes of Practice and Dubai Municipality require energy isolation procedures for maintenance, and most sites adopt OSHA 1910.147 as the recognised model. Each isolation must be locked by every person at risk, with tags identifying the authorised person, date and reason. Civil Defence and DEWA or ADDC practice adds specific requirements for electrical isolation and proving dead before work.

Saudi Aramco GI 6.012 Isolation, Lockout and Use of Hold Tags and ADNOC HSE standards commonly require written isolation certificates, group lock boxes for multi-trade work and a master key held only by the permit issuer. Padlocks are inspected for damaged shackles and legible engraving, and tags are single-use. Kits are audited periodically against the site energy control procedure, and training records for authorised persons are maintained alongside.

How to choose

  1. Choose non-conductive nylon padlocks for electrical work and brass or steel for outdoor valve isolations exposed to heat
  2. Select keyed-differently locks engraved per person; never share padlocks between workers
  3. Match breaker and valve lockouts to the actual equipment on site by surveying panel and valve types first
  4. Add a group lock box and permit board for turnarounds and multi-contractor isolations

Frequently asked questions

Is lockout-tagout mandatory in the UAE?

Energy isolation is required by OSHAD, Dubai Municipality and federal labour safety regulations for maintenance on machinery and electrical systems. Most UAE and Saudi sites adopt OSHA 1910.147 and ISO 45001 as the method, and ADNOC and Aramco require individual locks and tags on every isolation point under their permit systems.

What should a basic electrical LOTO kit contain?

Typically two or more personal padlocks keyed differently, a multi-lock hasp, universal MCB lockouts, an MCCB lockout, plug and cable lockouts, warning tags in Arabic and English, and a carry pouch. Mechanical kits add gate and ball valve lockouts and a group lock box for permits.

Should padlocks be keyed alike or keyed differently?

Personal padlocks must be keyed differently so only the worker who applied the lock can remove it. Keyed-alike sets are used only where one person holds all locks for a single isolation. Master keyed systems let the permit issuer recover a lock in a documented emergency removal.

Why use nylon padlocks instead of brass?

Nylon bodies and nylon shackles are non-conductive and non-sparking, suited to electrical panels and hazardous areas. They also resist corrosion in humid coastal plants. Brass or steel shackles give more cutting resistance for outdoor valves and gates where impact and heat are the main concerns.

Can you supply engraved padlocks and Arabic tags in bulk?

Yes. Al Baraka Diyar supplies padlocks laser-engraved with employee names or numbers, Arabic and English tags, and complete kits or wall stations from Ajman across the UAE, with service to Saudi Arabia and India. Lead time for engraved locks is typically one to two weeks.

Request a quote

Quote for Lockout-Tagout (LOTO) Kits

Tell us quantity, sizes and delivery location. We reply with an itemised quotation and certificates within one working day.

Download technical datasheet (PDF)

Get a quotation

Need Lockout-Tagout (LOTO) Kits for your site?

Send us the quantity, sizes and delivery location, or the client standard you must meet, and we will return an itemised quotation with certificates within one working day.

Chat on WhatsApp